XLG 75W 24V 1 1024x1024

XLG-75-24V

XLG-75-24V

1,600.00

+ Free Shipping

XLG-75 series is a 75W LED AC/DC driver featuring the constant power mode.XLG-75 operates from 100~305VAC and offers models with different rated current ranging between 700mA and 5000mA. Thanks to the high efficiency up to 91%, with the fanless design, the entire series is able to operate for – 40℃~+90℃ case temperature under free air convection. The design of metal housing and lP67 ingress protection level allows this series to fit both indoor and outdoor applications. Moreover the innovative environment-adaptive capability allows this series to reliably light on the LEDs for all kinds of application environments in almost any spots that may install LED luminaires in the world. XLG-75 series comply with the latest version of lEC61347/GB19510.1 and UL8750 international safety regulations. The output and dimming circuit are also completely in accordance with the new regulations with isolation to ensure the safety of both user and luminaire system during installation.

Availability: 10 in stock

- +
Add to Wishlist

Features

  • Wide input range 100~305V AC( ClassⅠ)
  • Full power output at 70~100% Constant power mode operation
  • Metal case with lP67, suitable for outdoor application
  • Class 2 power unit(except for L type)
  • Surge protection with 6KV/4KV
  • 3 in 1 dimming function (Dim to off and lsolation design)
  • lndia (EESL) version with lnput Over Voltage Protection can survive input voltage stress of 440Vac for 48 hours
  • Protection functions: OVP/SCP/OCP/OTP
  • Compliance to EN60335-1 household application
  • Life time >50,000 hrs. and 5 years warranty

Applications

  • Skyscraper lighting
  • Street lighting
  • Floodlight Lighting
  • Stage lighting
  • Horticulture lighting
  • Bay lighting
  • DMX power supply
  • Type HL for use in class l, Division 2
  • Household devices
  • Retail and refrigerated display

Description

XLG-75 series is a 75W LED AC/DC driver featuring the constant power mode.XLG-75 operates from 100~305VAC and offers models with different rated current ranging between 700mA and 5000mA. Thanks to the high efficiency up to 91%, with the fanless design, the entire series is able to operate for – 40℃~+90℃ case temperature under free air convection. The design of metal housing and lP67 ingress protection level allows this series to fit both indoor and outdoor applications. Moreover the innovative environment-adaptive capability allows this series to reliably light on the LEDs for all kinds of application environments in almost any spots that may install LED luminaires in the world. XLG-75 series comply with the latest version of lEC61347/GB19510.1 and UL8750 international safety regulations. The output and dimming circuit are also completely in accordance with the new regulations with isolation to ensure the safety of both user and luminaire system during installation.

Specification

MODEL XLG-75 -12- XLG-75 -24-
 

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE 12V 24V
CONSTANT CURRENT REGION Note.2 8.4~ 12V 16.8~ 24V
RATED CURRENT (Default) 5A 3.1A
RATED POWER 60W 74.4W
RIPPLE & NOISE (max.) Note.3 150mVp-p 240mVp-p
CURRENT ADJ RANGE 2.5A~5A 1.55A~3.1A
VOLTAGE TOLERANCE Note.4 ±3.0% ±2.0%
LINE REGULATION ±0.5% ±0.5%
LOAD REGULATION ±2% ±1%
SETUP, RISE TIME Note.6 500ms, 100ms/230VAC, 1200ms, 100ms/115VAC
HOLD UP TIME (Typ.) 10ms/ 230VAC 10ms/ 115VAC
 

 

 

 

 

 

INPUT

VOLTAGE RANGE                           Note.5 100 ~ 305VAC         142 ~ 431VDC

(Please refer to “STATIC CHARACTERISTIC” section)

FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
TOTAL HARMONIC DISTORTION THD< 10%(@load¾50%/115VC,230VAC; @load¾75%/277VAC)
EFFICIENCY (Typ.) 89% 90%
AC CURRENT 1.0A / 115VAC  0.45A / 230VAC  0.38A/277VAC
INRUSH CURRENT(Typ.) COLD START 50A(twidth=300μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER 9 units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT <0.75mA / 277VAC
NO LOAD

POWER CONSUMPTION

No load power consumption <0.5W(for standard version)
 

 

 

 

PROTECTION

OVER CURRENT 110~160% for CV type, 95~108% for other type
CV-type: Hiccup mode only; Other type: Hiccup or constant current limiting; Recovers automatically after fault condition is removed
SHORT CIRCUIT CV-type: Hiccup mode only; Other type: Hiccup or constant current limiting; Recovers automatically after fault condition is removed
OVER VOLTAGE 13 ~ 19V 26 ~ 36V
Shut down output voltage, re-power on to recover
 

INPUT OVER VOLTAGE

320 ~ 370VAC (Shut down output voltage when the input voltage exceeds protection voltage, recovers automatically after fault condition is removed)
Can survive input voltage stress of 440Vac for 48 hours(Input over voltage only for XLG-75I series)
OVER TEMPERATURE Shut down output voltage, re-power on to recover
 

 

 

 

ENVIRONMENT

WORKING TEMP. Tcase=-40 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP. Tcase=+90℃
WORKING HUMIDITY 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 60℃)
VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
 

 

 

 

 

 

 

 

 

 

 

 

EMC SAFETY &

SAFETY STANDARDS Note.7 UL8750(type”HL”), UL879, CSA C22.2 No. 250.13-12;ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384,EN 60335-1 compliant to EN 60335-2-89 Annex BB, EN 60335-2-24 Annex CC;GB19510.1, GB19510.14; EAC TP TC 004;J61347-1(H29), J61347-2-13(H29),

KC61347-1,KC61347-2-13,IS15885(Part2/Sec13)(for XLG-75I type only); OM-058-SCFI-2017(except for Blank type);IP67 approved

WITHSTAND VOLTAGE I/P-O/P:3.75KVAC  I/P-FG:2KVAC  O/P-FG:1.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
 

 

 

EMC EMISSION

Parameter Standard Test Level/Note
Conducted BS EN/EN55015(CISPR15) ,GB/T 17743 —–
Radiated BS EN/EN55015(CISPR15) ,GB/T 17743 —–
Harmonic Current BS EN/EN61000-3-2 ,GB17625.1 Class C @load≥50%
Voltage Flicker BS EN/EN61000-3-3 —–
 

 

 

 

 

EMC IMMUNITY

BS EN/EN61547
Parameter Standard Test Level/Note
ESD BS EN/EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact
Radiated BS EN/EN61000-4-3 Level 3
EFT/Burst BS EN/EN61000-4-4 Level 3
Surge BS EN/EN61000-4-5 4KV/Line-Line 6KV/Line-Earth
Conducted BS EN/EN61000-4-6 Level 3
Magnetic Field BS EN/EN61000-4-8 Level 4
Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods,

>95% interruptions 250 periods

 

OTHERS

MTBF 3404.7K hrs min.  Telcordia SR-332 (Bellcore) ;  276.3Khrs min.  MIL-HDBK-217F (25℃)
DIMENSION 140*63*32mm (L*W*H)
PACKING 0.58Kg;24pcs /15Kg /0.85CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.

2. Please refer to “DRIVING METHODS OF LED MODULE”. (Except for CV-type)

3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

4. Tolerance : includes set up tolerance, line regulation and load regulation.

5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.

6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.

7. Only CE/ENEC/CB is available for CV-type. XLG-75I series without UL/CSA certificate.

8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)

9. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.

10. Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com

11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

12. Products sourced from the Americas regions may not have the PSE/CCC/BIS/KC logo. Please contact your MEAN WELL sales for more information.

13. To fullfill requirements of the latest ErP regulation for lighting fixtures, this LED drivers can only be used behind a switch without permanently connected to the mains.

14. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf

15. If you need the NOM (Mexico) certificate, Please contact MEAN WELL sales representative for details.

16. For A/AB type need to consider build in using to comply with Type HL application.

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx                           File Name:XLG-75-SPEC  2024-10-11

Weight 0.58 kg
Dimensions 140 × 63 × 32 cm

Reviews

There are no reviews yet.

Be the first to review “XLG-75-24V”

Your email address will not be published. Required fields are marked *

You may also like…

  • LPV-35W-12V
    LPV Series 965.00
Shopping Cart
XLG-75-24VXLG-75-24V
1,600.00

Availability: 10 in stock

- +
Add to Wishlist
Scroll to Top
WordPress Outlet Zest: Multi-Concept React Admin Template Zeus – Gym & Fitness Elementor Template Kit Zeve – Tailor Service Elementor Template Kit Ziga – Healer & Life Coach Elementor Template Kit Zilom – Online Education Learning Elementor Template Kit ZimmyPet – Pet Care & Store Elementor Template Kit Zinancial – Finance & Accounting Services Elementor Template Kit Zingbox – Wind & Solar Energy Elementor Template Kit Ziston – Directory & Listings Elementor Template Kit Zitshoe – Shoes Cleaning Service Elementor Template Kit